Concrete Footing Calculator

Size the concrete for a footing run — strip footings under walls, pads under posts — and check that the width you picked can actually carry the load on the soil you have.

Trench widthDepth
Quick presets:
For individual pads, enter one footing and set the count below. Please check this value.
Please check this value.
Please check this value.
Please check this value.
Extra % for spillage and uneven trench bottoms. Please check this value.
Used only for the bearing check — centering matters. Please check this value.
Roof + floor + wall weight in pounds. If unsure, leave blank. Please check this value.
Please check this value.
Please check this value.

How to use this tool

  1. Measure the run. For a wall footing, that is the total centerline length of the wall. For isolated pads under posts, enter one pad's length and width and set the count.
  2. Set width and thickness. The tool starts at 16 in wide × 8 in thick — a common single-story residential footing. Width does more work than thickness: it spreads the load across the soil.
  3. Optionally run the bearing check. Enter the load the footing carries (roughly: roof + floor loads plus the wall's own weight) and pick the soil type. The tool compares what the soil can carry against your load.
  4. Enter your local price for a material line. Small footing jobs are often bagged; check the bag counts.

How the result is calculated

Volume (ft³) = length (ft) × width (ft) × thickness (ft) × number of footings, times your waste factor, divided by 27 for cubic yards.

Bearing check (optional): allowable load = soil allowable bearing pressure (psf) × footing width (ft) × footing length (ft) × count. The pressures offered — 1,500 psf for clay/silt/unknown up to 4,000 psf for sedimentary rock — are the conservative presumptive values long used by US model codes for preliminary sizing. They are starting points only: real allowable bearing depends on moisture, depth and local practice, and a geotechnical report overrides them.

Choosing the right numbers

Footings are sized by width first. The footing spreads the building's weight over the soil; doubling the width halves the pressure. Typical starting points for light residential work:

What it carriesTypical widthTypical thickness
Single-story exterior wall, light frame12–16 in6–8 in
Two-story wall or heavy cladding16–24 in8–12 in
Deck post (isolated pad)12–16 in square8–10 in
Interior bearing wall over firm soil12–16 in6–8 in

Depth below grade matters as much as size: the bottom of the footing must sit at or below the local frost line, on undisturbed or compacted soil. A footing that spans soft pockets will crack regardless of how strong the concrete is. Two continuous #4 (1/2 in) rebars are the common minimum reinforcement in an 8 in footing; larger or heavily loaded footings are engineered, not guessed.

Common mistakes to avoid

  • Stepping the footing on sloped ground without design. Long runs across slopes are stepped in jumps of at most a course or two; long tapering pours are a structural weak point.
  • Ignoring the frost line. A footing above it moves every winter and eventually cracks whatever it supports.
  • Pouring on loose backfill. Fresh fill settles for years; the footing needs undisturbed soil or engineered compaction.
  • Trusting the bearing check as a design. It uses presumptive soil values — a real design needs your site's actual soil, which is what a geotechnical report or local engineer provides.
  • Forgetting the count. One extra pad per pier line is easy to leave out of the order.

Worked examples

Example — 40 ft strip footing, 16 in × 8 in, 10% waste

Volume = 40 × 1.333 × 0.667 ≈ 35.6 ft³. With waste ≈ 39.1 ft³ ≈ 1.45 yd³ — about 66 of the 80 lb bags, or a 1.5-yard short-load.

Example — 6 deck pads, 16 in × 16 in × 8 in

Each pad = 1.333 × 1.333 × 0.667 ≈ 1.19 ft³; six pads ≈ 7.1 ft³. With 10% waste ≈ 7.8 ft³ ≈ 0.29 yd³ — roughly 13 bags of 80 lb mix, so bag it.

Bearing check — 16 in wide, 40 ft, 12,000 lb on sand

Capacity = 2,000 psf × 1.333 ft × 40 ft ≈ 106,000 lb — roughly a 9× margin against 12,000 lb. Comfortable.

Frequently asked questions

How wide should a footing be for a wall?

For light single-story framing, 12–16 in wide is the common starting point on ordinary soils; two-story or masonry-veneer walls often need 16–24 in. Run the bearing check above with your load, and treat the presumptive soil values as a floor — your local code table or an engineer gives the real answer.

How deep do footings need to be?

The bottom of the footing must be at or below the frost line in freezing climates, typically 12 in or more below grade even where frost is shallow, and on undisturbed soil. Local code sets the exact minimum.

Bags or ready-mix for footings?

Under roughly 1 yd³, bags are practical — about 45 bags of 80 lb mix. Above that, a short-load truck usually beats hand mixing both in cost and in the fatigue of finishing 45+ bags in one go.

Does rebar change how much concrete I need?

Negligibly. Steel displaces only a tiny volume; keep your waste factor honest instead of adjusting for bars.

Assumptions, sources and limits

  • Plain rectangular footings of uniform section on prepared, level ground; no haunches, keyways or stepped sections.
  • Bag yields use standard US figures (80 lb ≈ 0.60 ft³, 60 lb ≈ 0.45 ft³).
  • Soil bearing pressures are conservative presumptive code values for preliminary checks — not a substitute for site-specific soils data or an engineered design.
  • The bearing check assumes the load is centered and evenly spread; eccentric loads change the answer materially.
  • Prices come only from your own input.

Planning estimates only. Footing size, depth and reinforcement must follow your local code and, for structural loads, a qualified designer.