How to use this tool
- Set the shaft diameter and length as drilled — length from cut-off elevation to the bottom of the straight section.
- Add the bell only if the design has one. An under-ream spreads the load at the bottom in weak soils; enter its diameter and vertical height and the shaft length should stop at the bell's top.
- Keep 10% waste unless the boring log is dry and clean — wet holes, sloughing sides and tremie pours all eat concrete.
- Read per-pile first. It is the sanity check: a 12 in pile 10 ft deep should be about 0.29 yd³; if the group total doesn't divide back to that, a count is off.
How the result is calculated
Straight shaft: π × (diameter ÷ 2)² × length. With an under-ream, the shaft length runs to the top of the bell and the bell itself is a frustum: π × height ÷ 3 × (R² + R·r + r²), where R is the bell radius and r the shaft radius. Both × pile count × waste factor; 1 yd³ = 27 ft³. Bag counts use standard US yields (80 lb ≈ 0.60 ft³) — although real pile work is a ready-mix or tremie pour.
Choosing the right numbers
Piles carry load two ways — skin friction along the shaft and end bearing at the bottom — which is why diameter and depth matter more than grade of concrete for volume planning. Per 10 ft of depth, straight shafts:
| Shaft diameter | Concrete per 10 ft |
|---|---|
| 8 in | ≈ 0.13 yd³ |
| 12 in | ≈ 0.29 yd³ |
| 16 in | ≈ 0.52 yd³ |
| 18 in | ≈ 0.66 yd³ |
A bell can double or triple a pile's volume while roughly tripling its end-bearing area — useful in soft clays where depth alone can't find competent soil. Pile sizing, bell geometry and concrete grade are geotechnical outputs: this tool prices the design, it doesn't make it.
Common mistakes to avoid
- Running shaft length through the bell. The straight section stops at the bell's top; running it to the toe double-counts the frustum's core.
- Starving the waste factor in wet holes. Water and sloughing over-ream the bore; a dry 10% hole and a wet one can differ by real yards.
- Assuming the drilled diameter is the named diameter. Augers wander and bells over-ream; log the actual bores and keep waste honest.
- Counting piles from the layout, not the drill log. Refusals and re-drills change the count — reconcile the log before the plant ticket is written.
Worked examples
Example — 12 piles, 12 in × 12 ft straight shafts, 10% waste
Each = π × 0.5² × 12 ≈ 9.42 ft³ → group ≈ 113.1 ft³; with waste ≈ 124.4 ft³ ≈ 4.61 yd³.
Example — 4 piles, 12 in × 10 ft with 24 in × 18 in bells
Shaft each = π × 0.5² × 10 ≈ 7.85 ft³. Bell (frustum, R = 1 ft, r = 0.5 ft, h = 1.5 ft) ≈ (π × 1.5 ÷ 3) × (1 + 0.5 + 0.25) ≈ 2.75 ft³. Four piles ≈ 42.4 ft³; with 10% waste ≈ 46.7 ft³ ≈ 1.73 yd³.
Frequently asked questions
How much concrete is in a 12 inch pile?
Per foot of depth, π × 0.5² × 1 ≈ 0.785 ft³ ≈ 0.029 yd³. A 10 ft pile is about 0.29 yd³; a 12 ft pile about 0.35 yd³ — roughly 13–14 bags of 80 lb mix per pile if you were bagging (which, for real pile work, you wouldn't).
What is a belled pile?
A bored pile whose bottom is under-reamed into a wider "bell" — often 2–3× the shaft diameter — so the load spreads over far more soil at the base. The bell is a frustum; this calculator computes its volume from the bell diameter and vertical height you enter.
Why is pile waste higher than slab waste?
Bored holes over-pour: sides cave, water displaces, and the actual bore is rarely the nominal diameter. 10% is a fair planning number for wet or unstable holes; dry, cased holes run closer to 5%.
Assumptions, sources and limits
- Cylindrical shafts of the nominal drilled diameter and frustum bells of the entered geometry; no allowance for casing, tremie pipes or slurry displacement beyond the waste factor.
- Bag yields use standard US figures (80 lb ≈ 0.60 ft³); pile pours are ready-mix work in practice.
- Bell volume assumes the under-ream is fully formed as designed — caving or partial bells change the pour reality.
- Prices come only from your own input.
Planning estimates for pricing an existing design. Pile diameter, depth, bell geometry and concrete specification come from a geotechnical design — never from a volume calculator.