How to use this tool
- Choose the shape. Tube-formed round piers are the default for decks and crawlspace piers; square formed columns appear where the pier is exposed or carries masonry.
- Measure the column height from the top of its pad to the finish elevation — the pad sits below and is counted separately by the tool.
- Add the pad if there is one. A flared or square pad under each pier is what spreads the load; on soft or unknown soils it is not optional in practice.
- Set the count and read the whole-run totals — per-column numbers are shown so you can sanity-check one pier by hand.
How the result is calculated
Round columns: π × (diameter ÷ 2)² × height; square columns: side² × height. When a pad is selected, add its volume — π × (pad diameter ÷ 2)² × thickness for a round flare, width² × thickness for a square pad — once per column. The run total multiplies by the column count and your waste factor; 1 yd³ = 27 ft³. Bag counts use standard US yields (80 lb ≈ 0.60 ft³, 60 lb ≈ 0.45 ft³).
Choosing the right numbers
Piers compress the footing and column into one element. The pad's job is bearing (spreading load on soil); the shaft's job is reaching frost depth and holding the post above grade. Common residential pairings:
| Use | Shaft | Pad |
|---|---|---|
| Crawlspace girder pier | 12×12 in square or 12 in round | 16×16×8 in square |
| Deck post, moderate soil | 10–12 in round tube | 16 in round × 8 in |
| Deck post, soft or fill soil | 12–16 in round tube | 20–24 in × 10 in, or engineered |
| Light outbuilding corner | 10 in round tube | 14–16 in × 8 in |
Depth is not a style choice: the pad bottom belongs at or below frost depth on undisturbed soil. Where loads are heavier than a deck or a girder — room additions, second stories — the sizes stop being rules of thumb and become an engineer's numbers.
Common mistakes to avoid
- Counting the pad twice. A "flared tube" pour is one continuous volume; the calculator adds shaft + pad once. If you pour the pad separately the total is unchanged — just don't add the pad by hand on top.
- Measuring shaft height including the pad. That double-counts the overlap; height runs from the pad's top surface.
- Sizing pads from habit on fill soil. Fresh fill consolidates for years; pads there need real bearing numbers, not the table above.
- Mixing shapes mid-run. Enter one shape, finish the pour, then run the tool again for the other shape — a blended average costs more than it saves.
- Skipping the waste factor on small pours. Five piers × 0.15 yd³ each rounds badly; 5–10% waste is what actually lands in the holes.
Worked examples
Example — 8 deck piers: 12 in round shafts, 40 in tall, on 16 in round × 8 in pads
Shaft each = π × 0.5² × 3.33 ≈ 2.62 ft³; pad each = π × (8/12)² × 0.667 ≈ 0.93 ft³. Combined ≈ 3.55 ft³ × 8 = 28.4 ft³; with 5% waste ≈ 29.8 ft³ ≈ 1.10 yd³.
Example — 6 crawlspace piers, 12×12 square, 24 in tall, 16×16×8 pads
Shaft each = 1 × 1 × 2 = 2 ft³; pad each = 1.333 × 1.333 × 0.667 ≈ 1.19 ft³. Six of each ≈ 19.1 ft³; with waste ≈ 20.1 ft³ ≈ 0.74 yd³ — about 34 bags of 80 lb.
Frequently asked questions
How much concrete does one 12 inch pier take?
Per foot of height, π × 0.5² × 1 ≈ 0.79 ft³, so a 40 in shaft is about 2.6 ft³ — roughly 0.10 yd³ or 4–5 bags of 80 lb mix. A footing pad under it adds about 0.03 yd³ more per inch of thickness.
Round tube or square formed pier?
Round tube-formed piers are cheaper and faster for buried work — the tube is the form. Square formed piers show up where the column is exposed, ties into blockwork, or the design calls for it. Structurally, for the light loads in the guide table, either works when sized right.
Do crawlspace piers need a pad?
In practice yes — even a modest 16×16×8 in pad spreads the girder load and keeps the pier from punching into soft spots. The pad also gives you a clean, level bearing surface to set the pier on.
Assumptions, sources and limits
- Prismatic shafts and flat pads of uniform thickness; flared pours are approximated as shaft + flat pad, which matches how they are usually formed.
- Bag yields use standard US figures (80 lb ≈ 0.60 ft³, 60 lb ≈ 0.45 ft³).
- Suggested sizes in the guide are common practice for light residential loads — not a structural design for your structure.
- Prices come only from your own input.
Planning estimates only. Pier and pad sizes must follow your local code and the design for the structure they carry.