Concrete Shed & Equipment Pad Calculator

A level pad is the difference between a shed that lasts decades and doors that never close again. Get the concrete, the gravel base and the cost in one pass.

WidthLengthThickness
Please check this value.
Please check this value.
Please check this value.
Please check this value.
Please check this value.
Extra % for spillage and uneven subgrade. Please check this value.
Compacted ¾ in minus gravel under the pad. Please check this value.
Pad is usually wider than the shed floor — enter the extra per side (added to both length and width). Please check this value.
Please check this value.

How to use this tool

  1. Enter the shed floor size (or equipment footprint), not the pad size — the tool adds the oversize per side itself.
  2. Leave oversize at 3 in unless the manufacturer specifies a larger pad; bigger pads shed splash onto the shed walls anyway.
  3. Keep 4 in thickness for storage sheds; 5 in for riding mowers or small tractors, 6 in for carports and boat pads.
  4. Enter a 4 in gravel base — pads set directly on soil tilt and crack within a few freeze cycles.

How the result is calculated

Volume (ft³) = length (ft) × width (ft) × thickness (ft) × number of areas, multiplied by your waste factor, then divided by 27 for cubic yards. Circular areas use π × (diameter ÷ 2)². Bag counts use standard US yields: an 80 lb bag yields about 0.60 ft³ of mixed concrete, a 60 lb bag about 0.45 ft³.

Oversize: the pad grows by 2 × oversize in both directions before volume is computed. Gravel base: pad length × width × base depth, quoted separately.

Choosing the right numbers

Typical pads at 4 in thick with 3 in oversize per side, on a 4 in gravel base:

UseFootprintPad sizeConcrete (yd³)
8×10 storage shed8 × 10 ft8.5 × 10.5 ft≈ 1.15
10×12 garden shed10 × 12 ft10.5 × 12.5 ft≈ 1.70
AC / heat pump3 × 4 ft3.5 × 4.5 ft≈ 0.23
Standby generator2.5 × 5 ft3 × 5.5 ft≈ 0.23

Small pads are bag territory — an AC pad is about ten 80 lb bags. Frost heave is the real design decision: in freeze country, a shed pad should either sit on well-drained compacted gravel below the organic layer or be tied to frost-depth footings at the corners. Check what your shed manufacturer honors under warranty.

Common mistakes to avoid

  • Level-ish is not level. Check the form with a 4 ft level in both directions and diagonally. Sheds racking out of square void warranties.
  • No anchor plan. Embed anchor bolts or straps while pouring — drilling cured concrete with masonry bits is nobody's idea of a good afternoon.
  • Pad flush with grade. Leave 2–3 in above grade so splash and mower strings hit concrete, not siding.
  • Ordering a truck for an AC pad. Under half a yard, bags or a short-load trailer beat plant minimums almost everywhere.

Worked examples

Example — 10 × 12 shed, 3 in oversize, 4 in pad, 4 in gravel

Pad = 10.5 × 12.5 ft. Volume = 131.25 × ⅓ = 43.75 ft³; with 10% waste ≈ 48.1 ft³ ≈ 1.78 yd³ — or about 80 of the 80 lb bags. Gravel base ≈ 1.62 yd³ delivered separately.

Frequently asked questions

How thick should a shed pad be?

4 in handles storage sheds and garden equipment. Use 5 in for riding mowers and 6 in if cars or boats will park on it.

How much bigger should the pad be than the shed?

About 2–4 in on each side is typical. It sheds splash away from walls and gives anchors margin. Enter the oversize and the tool enlarges the pad for you.

Do I need footings below the pad?

In frost country, many manufacturers want corner footings to frost depth or a deeply compacted free-draining base. Check your shed warranty and local code before ordering concrete.

Assumptions, sources and limits

  • Pad modeled as a flat uniform slab; no allowance for formed skirts, steps or ramps.
  • Oversize applies equally to length and width; gravel is calculated on the enlarged pad.
  • Bag yields: standard US figures. Frost and anchoring guidance is general practice, not a substitute for local code.

Planning estimates only.