How to use this tool
- Survey the low spots. Set a straightedge or laser level and mark the deepest dips — the difference between high and low across the room tells you the fill range.
- Enter the room size and your average fill depth (half the max dip is often a fair average for isolated lows).
- Check the product sheet for coverage per bag at ¼ in and enter it.
- Add bag price for the material total.
How the result is calculated
Volume (ft³) = length (ft) × width (ft) × thickness (ft) × number of areas, multiplied by your waste factor, then divided by 27 for cubic yards. Circular areas use π × (diameter ÷ 2)². Bag counts use standard US yields: an 80 lb bag yields about 0.60 ft³ of mixed concrete, a 60 lb bag about 0.45 ft³.
Self-leveler bags: product coverage is rated at a ¼ in depth. The tool scales it to your average fill depth (a ½ in pour uses twice as many bags), applies the waste factor, and rounds up to whole bags.
Choosing the right numbers
Self-leveling compound is a topping, not a repair for a moving slab:
- Depth matters: most products pour happily from ⅛ to 1 in in one pass; deeper fills need multiple passes or a bulk-fill product. Check the sheet.
- Prime first. Almost every system needs a diluted primer coat on porous concrete — skip it and you get pinholes and weak bond.
- Move fast: mixed leveler flows for 10–20 minutes. Spread with a squeegee and spike shoes; it finds its own level but needs encouragement into corners.
- Feather edges with a trowel where the pour meets high ground so there is no lip at the door.
A 12 × 15 ft room with a ½ in average fill runs roughly 270 sq ft·in ÷ (0.25 × 25 sq ft per bag) ≈ 11 bags — the tool does this arithmetic for you.
Common mistakes to avoid
- No depth survey. Guessing leads to pouring thin where it is deep and drowning the high spots. Survey first, then buy.
- Leveling over loose paint or adhesive. Grind or strip first — leveler bonds to concrete, not to whatever used to be there.
- Ignoring movement cracks. Bridge them with tape or filler or they reappear in the new surface.
- Cold floors. Below about 50 °F the compound never reaches strength; warm the room before mixing.
Worked examples
Example — 12 ft × 15 ft room, ½ in average fill, 25 sq ft/bag at ¼ in
Area = 180 ft². Effective coverage need = 180 × (0.5 ÷ 0.25) = 360 ft²·at-¼in. With 10% waste ≈ 396 → 396 ÷ 25 = 15.8 → 16 bags. At $35/bag ≈ $560 in material.
Frequently asked questions
How many bags of self-leveler per 100 sq ft?
At ¼ in depth and typical 20–30 sq ft/bag coverage, plan on 4–5 bags per 100 sq ft. Double it for a ½ in pour — the tool scales automatically from your average depth.
How deep can self-leveling compound be poured?
Most polymer levelers handle ⅛–1 in in one pass; some bulk products go to 2 in or more in layers. Check the data sheet for the single-pour limit.
Do I need to prime before leveling?
Yes on porous concrete — nearly every system requires a primer coat to prevent pinholes and secure bond. Unprimed pours fail at the edges first.
Assumptions, sources and limits
- Coverage and pricing come entirely from the product data you enter; no brand is assumed.
- Average fill depth is yours to estimate from the survey — the tool does not invent it.
- Applies to interior slabs and subfloors rated for the product; exterior leveling compounds differ.
Planning estimates only; follow the manufacturer's instructions.