How to use this tool
- Enter the span between supports — walls, beams or bearing lines that actually support the strip.
- Set thickness and strength as designed or as poured.
- Enter the live load the slab carries beyond itself — furniture, people, stored goods.
- Read both deflection lines. Live-load-only deflection is what occupants feel; total load (with self-weight) is what the structure experiences.
How the result is calculated
The classic elastic beam check applied to a 1-ft-wide strip of slab: δ = 5wL⁴ ÷ (384EI) simply supported, ÷5 of that fixed-ended, where E ≈ 57,000 × √f'c psi (the ACI short-term estimate) and I = b·h³ ÷ 12 with b = 12 in. Loads include the slab's self-weight (150 lb/ft³ × thickness) plus your live load. The reported ratio compares total-load deflection against the span — L/360 is the common comfort limit for live load, L/240 the looser total-load bar.
Choosing the right numbers
Where common residential spans land with the strip check (4,000 psi):
| Span | Thickness | L/h | Gross-section verdict |
|---|---|---|---|
| 8 ft | 4 in | 24 | Comfortable — and stays so after cracked/creep reality |
| 10 ft | 5 in | 24 | Comfortable |
| 12 ft | 6 in | 24 | Comfortable |
| 12 ft | 4 in | 36 | Gross check passes — but L/h 36 flags it: cracking + creep eat the margin |
| 16 ft | 6 in | 32 | Gross check passes — L/h 32 says get a design before trusting it |
The honest framing, again: this check assumes an uncracked elastic strip. Real reinforced slabs crack at the tension face, effective stiffness drops (often to a fraction of the gross I), and creep multiplies long-term deflections by 2–3× over years. That is precisely why span-to-thickness rules of thumb (L/h ≈ 24–28 for one-way floors) exist — they bake the cracked-and-crept reality into a simple ratio. Treat the gross-section pass as necessary, not sufficient: when L/h climbs past ~28, the margin the elastic math shows is margin reality will spend.
Common mistakes to avoid
- Trusting gross-section math for final answers. Uncracked I overstates stiffness; real slabs deflect 2–4× this figure over their life. The verdict bands above are deliberately forgiving.
- Forgetting self-weight. At 6 in, the slab carries 75 psf of itself before your furniture arrives — the tool includes it; mental math often doesn't.
- Spanning without support lines. "Slab-on-grade" doesn't span at all — the ground carries it. This check is for elevated slabs and spanning conditions only.
- Ignoring two-way action. Slabs spanning both directions share load — a one-way strip check is conservative there, but the real behavior is a design question.
- Long spans by habit. Every span step costs thickness cubed — check L/h before committing a floor plan.
Worked examples
Example — 12 ft span, 6 in slab, 4,000 psi, 50 psf live
E ≈ 3.6M psi; I = 216 in⁴ per foot. Self-weight 75 psf + 50 = 125 psf → δ ≈ 0.075 in total; live load alone ≈ 0.03 in. L/δ ≈ 1,900 — comfortable on the gross section, and L/h = 24 keeps it honest after cracking and creep.
Example — same span at 4 in
I drops to 64 in⁴ (h³ scaling) → total δ ≈ 0.20 in, L/δ ≈ 710 — the gross check still passes. But L/h = 36, and at 3–4× real multiplier after cracking and creep, the working deflection lands near 0.6–0.8 in — L/180 to L/240, where floors feel lively. The cube law: 2/3 the thickness, 3.4× the deflection.
Frequently asked questions
How much does a concrete slab deflect?
A well-proportioned elevated slab (L/h ≈ 24) deflects small fractions of an inch under live load short-term — then creeps to 2–3× that over years. The strip calculator above shows the short-term estimate; long-term design multiplies it.
What is the L over h ratio for slabs?
One-way floors commonly land at L/h ≈ 20–28 (span ÷ thickness). A 12 ft span at 6 in sits at L/h = 24 — the classic residential proportion. Push past ~28 and deflection starts ruling.
Does concrete strength reduce deflection?
Only weakly — E scales with √f'c, so doubling strength cuts deflection ~30%, while adding thickness cuts it cubically. Thickness is the deflection lever; strength is the strength lever.
Assumptions, sources and limits
- Elastic, uncracked gross section; short-term loads only (no creep, no shrinkage, no long-term multiplier).
- One-way strip behavior; two-way slabs distribute differently.
- E from the ACI short-term estimate (57,000√f'c); self-weight at 150 lb/ft³.
- Limits (L/360, L/240) are common serviceability conventions, not your project's specification.
Stiffness sanity check for spanning slabs. Real deflection design belongs to a qualified engineer.